|
21. Cuffless Blood Pressure Measurement: Where Do We Actually Stand?
Mukkamala R, Shroff SG, Kyriakoulis KG, Avolio AP, Stergiou GS.
+ Εμφάνιση Περίληψης
Cuffless blood pressure (BP) measurement offers considerable potential for clinical practice but is a challenging technological field. Many are investigating pulse wave analysis with or without pulse arrival time in which machine learning is applied to pulsatile waveforms obtained with mobile devices (eg, wristbands, smartphones) to estimate BP. These methods generally require individual user calibration with cuff BP measurements or demographics (eg, age, sex). This calibration makes it difficult to evaluate the method's accuracy, and many studies claiming accuracy used inadequate testing procedures. Yet, publications and regulatory-cleared devices continue to rise, seemingly implying technological advancements. An update is provided on the flurry of activity in cuffless BP technologies over the last 2 to 3 years, covering the clinical need, the latest devices, recent publications based on pulse wave analysis and pulse arrival time, progress in developing validation standards for cuffless BP devices, and recent publications on other cuffless BP measurement principles. Despite the high volume of research and development, to date, there is no compelling evidence that pulse wave analysis and pulse arrival time can provide significant added value in BP measurement accuracy beyond the cuff BP or demographic data for calibration. Thus, it is reasonable to at least be skeptical of published and future studies on pulse wave analysis and pulse arrival time for cuffless BP measurement with uncertain testing procedures. It is important to focus on establishing robust validation standards for cuffless BP devices requiring individual user calibration and also pursuing cuffless and calibration-free BP measurement methodologies going forward.
|
|
22. Benefits and Risks Associated With Statin Therapy for Primary Prevention in Old and Very Old Adults.
Kollias A, Kyriakoulis KG, Stergiou G.
|
|
23. Cardiovascular Risk Assessment and Lipid-Lowering Therapy Recommendations in Primary Prevention.
Komnianou A, Kyriakoulis KG, Menti A, Dimakakos E, Stergiou GS, Kollias A.
+ Εμφάνιση Περίληψης
Cardiovascular disease remains the leading cause of morbidity and mortality worldwide, underscoring the importance of effective primary prevention strategies. Current total cardiovascular disease (CVD) risk assessment tools, such as the Systematic Coronary Risk Evaluation 2 (SCORE2) in Europe and the Pooled cohort equations (PCEs) and Predicting Risk of CVD EVENTs (PREVENT) in the USA, aim to identify individuals at high CVD risk and guide clinical decision-making in the primary prevention setting. Statin therapy reduces cardiovascular events and is recommended as the first step for individuals with estimated CVD risk above specific thresholds. Moreover, the presence of risk modifiers, as well as the detection of asymptomatic atherosclerosis, reclassifies low-moderate CVD risk individuals into higher risk categories, contributing to tailored therapeutic decisions in primary prevention. However, differences in the performance of the available CVD risk assessment tools, the recommended thresholds for intervention, and the treatment targets by scientific societies introduce considerable inconsistency to the statin therapy practices. In addition, physicians' inertia and poor patients' adherence contribute to inadequate dyslipidemia control rates. This narrative review examines the available evidence on the current most used CVD risk assessment tools and the respective lipid-lowering recommendations, and highlights the role of targeted screening for asymptomatic atherosclerosis in terms of individualized therapy for primary prevention.
|
|
24. Hypertension and Atrial Fibrillation: A Frontier Review From the AF-SCREEN International Collaboration.
Niiranen TJ, Schnabel RB, Schutte AE, Biton Y, Boriani G, Buckley C, Cameron AC, Damasceno A, Diederichsen SZ, Doehner W, Guo Y, Hobbs FDR, Joung B, Hankey GJ, Lip GYH, Lobban T, Løchen ML, Mairesse G, Mbakwem A, Noseworthy PA, Ntaios G, Steinhubl S, Stergiou G, Svendsen JH, Tieleman RG, Wang J, Poulter NR, Healey JS, Freedman B.
+ Εμφάνιση Περίληψης
Hypertension is the leading modifiable risk factor for atrial fibrillation (AF) and is estimated to be present in >70% of AF patients. This Frontiers Review was prepared by 29 expert members of the AF-SCREEN International Collaboration to summarize existing evidence and knowledge gaps on links between hypertension, AF, and their cardiovascular sequelae; simultaneous screening for hypertension and AF; and the prevention of AF through antihypertensive therapy. Hypertension and AF are inextricably connected. Both are easily diagnosed, often silent, and frequently treated inadequately. Together, they additively increase the risk of ischemic stroke, heart failure, and many types of dementia, resulting in greater all-cause mortality, considerable disease burden, and increased health care expenditures. Automated upper arm cuff blood pressure devices with implemented technology can be used to simultaneously detect both hypertension and AF. However, positive screening for AF with an oscillometric blood pressure monitor still requires ECG confirmation. The current evidence suggests that high-risk individuals aged ≥65 years or with treatment-resistant hypertension could benefit from AF screening. Since antihypertensive therapy effectively lowers AF risk, particularly in individuals with left ventricular dysfunction, hypertension should be the key target for AF prediction and prevention rather than merely a comorbidity of AF. Nevertheless, several important gaps in knowledge need to be filled over the next years, including the ideal method and selection of patients for simultaneous screening of hypertension and AF and the optimal antihypertensive drug class and blood pressure targets for AF prevention.
|
|
25. Long-term event rates, risk factors, and treatment pattern in 1.4 million individuals qualifying for dual blood pressure lowering therapy.
Coca A, Borghi C, Stergiou GS, Ly NF, Lee C, Tricotel A, Castelo-Branco A, Khan I, Blacher J, Abdel-Moneim M.
|
|
26. Home versus routine dialysis-unit blood pressure recordings among patients on hemodialysis.
Leonidou K, Georgianos PI, Kollias A, Kontogiorgos I, Vaios V, Leivaditis K, Karligkiotis A, Stamellou E, Balaskas EV, Stergiou GS, Liakopoulos V.
+ Εμφάνιση Περίληψης
The optimal method for the diagnosis of hypertension among patients on hemodialysis remains a controversial issue. Using 44-h ambulatory blood pressure (BP) monitoring (ABPM) as the reference-standard, we assessed the diagnostic performance of home BP monitoring (HBPM) versus routine dialysis-unit BP recordings in hemodialysis patients. Over a period of 2 weeks, the following methods were used for the assessment of hypertension: (i) routine predialysis and postdialysis BP recordings averaged over 6 consecutive dialysis sessions; (ii) HBPM for 7 days (duplicate morning and evening measurements, Microlife WatchBP Home N); (iii) 44-h ABPM (20-min intervals over an entire interdialytic interval, Microlife WatchBPO3). The study included 70 patients (mean age: 65.3 ± 13.2 years; treated hypertensives: 87.1%; 44-h ambulatory systolic/diastolic BP: 120.6 ± 15.2/66.3 ± 10.1 mmHg). Mean (standard deviation) of the differences between ambulatory daytime systolic BP (SBP) and routine predialysis SBP was -11.4 (13.4) mmHg, routine postdialysis SBP -4.0 (15.1) mmHg and home SBP -8.6 (10.7) mmHg. The area under the receiver-operating-characteristic-curve (AUC) for the detection of an ambulatory daytime SBP ≥ 135 mmHg was higher for home SBP [AUC: 0.934; 95% confidence interval (CI): 0.871-0.996] relative to predialysis SBP (AUC: 0.778; 95% CI: 0.643-0.913) and postdialysis SBP (AUC: 0.766; 95% CI: 0.623-0.909) (P = 0.02 for both comparisons). Home SBP at the cut-off point of 141.0 mmHg provided the best combination of sensitivity (85.7%) and specificity (92.9%) in diagnosing hypertension. In conclusion, the present study shows that among hemodialysis patients, HBPM for 1 week is superior to 2-week averaged routine predialysis or postdialysis BP in predicting ambulatory hypertension.
|
|
27. Controversy in Hypertension: Pro-Side of the Argument Using Artificial Intelligence for Hypertension Diagnosis and Management.
Armoundas AA, Ahmad FS, Attia ZI, Doudesis D, Khera R, Kyriakoulis KG, Stergiou GS, Tang WHW.
+ Εμφάνιση Περίληψης
Hypertension presents the largest modifiable public health challenge due to its high prevalence, its intimate relationship to cardiovascular diseases, and its complex pathogenesis and pathophysiology. Low awareness of blood pressure elevation and suboptimal hypertension diagnosis serve as the major hurdles in effective hypertension management. Advances in artificial intelligence in hypertension have permitted the integrative analysis of large data sets including omics, clinical (with novel sensor and wearable technologies), health-related, social, behavioral, and environmental sources, and hold transformative potential in achieving large-scale, data-driven approaches toward personalized diagnosis, treatment, and long-term management. However, although the emerging artificial intelligence science may advance the concept of precision hypertension in discovery, drug targeting and development, patient care, and management, its clinical adoption at scale today is lacking. Recognizing that clinical implementation of artificial intelligence-based solutions need evidence generation, this opinion statement examines a clinician-centric perspective of the state-of-art in using artificial intelligence in the management of hypertension and puts forward recommendations toward equitable precision hypertension care.
|
|
28. Blood pressure variability: a review.
Kulkarni S, Parati G, Bangalore S, Bilo G, Kim BJ, Kario K, Messerli F, Stergiou G, Wang J, Whiteley W, Wilkinson I, Sever PS.
+ Εμφάνιση Περίληψης
Blood pressure variability (BPV) predicts cardiovascular events independent of mean blood pressure. BPV is defined as short-term (24-h), medium or long- term (weeks, months or years). Standard deviation, coefficient of variation and variation independent of the mean have been used to quantify BPV. High BPV is associated with increasing age, diabetes, smoking and vascular disease and is a consequence of premature ageing of the vasculature. Long-term BPV has been incorporated into cardiovascular risk models (QRISK) and elevated BPV confers an increased risk of cardiovascular outcomes even in subjects with controlled blood pressure. Long-acting dihydropyridine calcium channel blockers and thiazide diuretics are the only drugs that reduce BPV and for the former explains their beneficial effects on cardiovascular outcomes. We believe that BPV should be incorporated into blood pressure management guidelines and based on current evidence, long-acting dihydropyridines should be preferred drugs in subjects with elevated BPV.
|
|
29. Blood pressure measurement at kiosks in public spaces: systematic review and consensus statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability endorsed by the International Society of Hypertension and the World Hypertension League.
Stergiou GS, Kyriakoulis KG, Kollias A, McManus RJ, Menti A, Parati G, Schutte AE, Wang J, Asayama K, Asmar R, Bilo G, Chapman N, Fujiwara T, Head G, Kahn N, Kario K, Li Y, Manios E, Mariglis D, Mihailidou AS, Muntner P, Myers M, Niiranen T, Ohkubo T, Omboni S, Protogerou A, Saladini F, Sharman J, Shimbo D, De La Sierra A, Palatini P.
+ Εμφάνιση Περίληψης
Kiosk devices for unsupervised self-measurement of blood pressure (BP) are being used in public spaces and healthcare settings in several countries. This statement by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability provides a review of the published evidence on kiosk BP devices and consensus recommendations for their requirements and clinical use. A systematic literature search identified 54 relevant studies. Kiosk BP measurements appeared to be close to office BP [mean difference systolic 0.2 mmHg (95% confidence intervals -1.3 to 1.8); diastolic -0.4 mmHg (-3.5 to 2.7)], and higher than daytime ambulatory and home BP [mean difference 6.0 mmHg (1.6-10.4)/5.0 (2-8) and 8.1 mmHg (-2.6 to 18.9)/0.2 (-9.6 to 10.0), respectively]. Randomized or observational studies using kiosk BP measurements for hypertension screening or for assessing hypertension control were also included, as well as studies investigating users' and healthcare professionals' opinions, acceptability, and perspectives regarding kiosk BP measurements, and validation studies of kiosk BP devices. These studies had considerable heterogeneity in design, setting, methodology, measurement protocol, and sample size. Thus, at present, the clinical utility of kiosk BP measurements is uncertain. This ESH consensus statement acknowledges the potential of kiosk BP measurement as an emerging method for unsupervised self-measurement in the context of opportunistic screening for hypertension in apparently healthy people and the long-term monitoring of people with diagnosed hypertension. Requirements for the design, validation, function, and use of kiosk BP monitors are provided, together with the pending research questions on their optimal implementation in clinical practice.
|
|
30. How to validate the accuracy of automated blood pressure monitors in children: methodology, protocol, and challenges.
Menti A, Ntineri A, Theodosiadi A, Ntousopoulos V, Kollias A, Stergiou GS.
|
|
31. Out-of-office blood pressure monitoring in defining and confirming true resistant hypertension.
Kollias A, Kyriakoulis KG, Stergiou GS.
|
|
32. Mortality risks in different subtypes of masked hypertension in the Spanish ambulatory blood pressure monitoring registry.
de la Sierra A, Ruilope LM, Staplin N, Stergiou GS, Williams B.
|
|
33. A Randomized Controlled Trial on the Efficacy and Safety of a Calcium-Channel Blocker and an Angiotensin-Converting Enzyme Inhibitor in Chinese and European Patients with Hypertension.
Zhang W, Liu CY, Bilo G, Soranna D, Zambon A, Kyriakoulis KG, Kollias A, Ceravolo I, Cassago S, Pengo MF, Destounis A, Stergiou GS, Wang JG, Parati G.
|
|
34. May Measurement Month 2022: results from the global blood pressure screening campaign.
Beaney T, Kerr GK, Kiru G, McArdle H, Schlaich M, Schutte AE, Stergiou GS, Wang JG, Marin MJ, Henandez-Hernandez R, Diaz ABF, Alcocer L, Lopez-Jaramillo P, Poulter N.
|
|
35. Home Blood Pressure Measurements Are Not Performed According to Guidelines and Standardized Education Is Urgently Needed.
Clapham E, Picone DS, Carmichael S, Stergiou GS, Campbell NRC, Stevens J, Batt C, Schutte AE, Chapman N.
|
|
36. Screening for Atrial Fibrillation During Routine Automated Blood Pressure Measurement in General Population Aged 65 Years and Above: EMENO National Epidemiological Survey in Greece.
Menti A, Kalpourtzi N, Kyriakoulis KG, Kollias A, Touloumi G, Stergiou GS.
|
|
37. The impact of the COVID-19 Pandemic on hypertension phenotypes (ESH ABPM COVID-19 study).
Ostrowska A, Wojciechowska W, Rajzer M, Weber T, Bursztyn M, Persu A, Stergiou G, Kiełbasa G, Chrostowska M, Doumas M, Parati G, Bilo G, Grassi G, Mancia G, Januszewicz A, Kreutz R.
|
|
38. The impact of the COVID-19 pandemic on blood pressure control in patients with treated hypertension-results of the European Society of Hypertension Study (ESH ABPM COVID-19 Study).
Wojciechowska W, Rajzer M, Kreutz R, Weber T, Bursztyn M, Persu A, Stergiou G, Parati G, Bilo G, Pac A, Grassi G, Mancia G, Januszewicz A, Chrostowska M, Narkiewicz K, Dubiela A, Doumas M, Imprialos K, Stavropoulos K, de Freminville JB, Azizi M, Cunha PG, Lewandowski J, Strzelczyk J, Wuerzner G, Gosk-Przybyłek M, Szwench-Pietrasz E, Prejbisz A, Van der Niepen P, Kahan T, Jekell A, Spaak J, Tsioufis K, Ehret G, Doroszko A, Kubalski P, Polonia J, Styczkiewicz K, Styczkiewicz M, Mazur S, Veglio F, Rabbia F, Eula E, Águila FJ, Sarzani R, Spannella F, Jarai Z, Papadopoulos D, Lopez-Sublet M, Ostrowska A, Grassos C, Kahrimanidis I, Eugenia G, Areti T, Tomasz G, Barbara W, Aleksandra S, Beata M, Angeliki N, Robles NR, Widmiski J, Zbroch E.
|
|
39. Innovations in blood pressure measurement and reporting technology: International Society of Hypertension position paper endorsed by the World Hypertension League, European Society of Hypertension, Asian Pacific Society of Hypertension, and Latin American Society of Hypertension.
Kario K, Williams B, Tomitani N, McManus RJ, Schutte AE, Avolio A, Shimbo D, Wang JG, Khan NA, Picone DS, Tan I, Charlton PH, Satoh M, Mmopi KN, Lopez-Lopez JP, Bothe TL, Bianchini E, Bhandari B, Lopez-Rivera J, Charchar FJ, Tomaszewski M, Stergiou G.
+ Εμφάνιση Περίληψης
Blood pressure (BP) is a key contributor to the lifetime risk of preclinical organ damage and cardiovascular disease. Traditional clinic-based BP readings are typically measured infrequently and under standardized/resting conditions and therefore do not capture BP values during normal everyday activity. Therefore, current hypertension guidelines emphasize the importance of incorporating out-of-office BP measurement into strategies for hypertension diagnosis and management. However, conventional home and ambulatory BP monitoring devices use the upper-arm cuff oscillometric method and only provide intermittent BP readings under static conditions or in a limited number of situations. New innovations include technologies for BP estimation based on processing of sensor signals supported by artificial intelligence tools, technologies for remote monitoring, reporting and storage of BP data, and technologies for BP data interpretation and patient interaction designed to improve hypertension management ("digital therapeutics"). The number and volume of data relating to new devices/technologies is increasing rapidly and will continue to grow. This International Society of Hypertension position paper describes the new devices/technologies, presents evidence relating to new BP measurement techniques and related indices, highlights standard for the validation of new devices/technologies, discusses the reliability and utility of novel BP monitoring devices, the association of these metrics with clinical outcomes, and the use of digital therapeutics. It also highlights the challenges and evidence gaps that need to be overcome before these new technologies can be considered as a user-friendly and accurate source of novel BP data to inform clinical hypertension management strategies.
|
|
40. General and abdominal adiposity and hypertension in eight world regions: a pooled analysis of 837 population-based studies with 7·5 million participants.
|